KTeV KL->e e gamma plots
Updated August 9, 2007.
[KL->eeg Results]
-
trdcut.eps,
trdcut.pdf
Fig. 1: The reconstructed e+e-gamma mass distribution before and after the TRD cut shows a significant decrease in the amount of backgroudn while retaining most of the signal. The signal region is indicated by the two vertical lines centered on the kaon mass.
-------------------------------------------------------
-
bms_cv.eps,
bms_cv.pdf
Fig. 2: The variation in the shape of the e+e- mass distribution was used to determine the values of the form factor parameters. Three comparisons between data (dots) and Monte Carlo samples (histogram) with different values of Calpha K* are shown as well sas the final fit to the shape chi2 values.
-------------------------------------------------------
-
akstar_comparison.eps,
akstar_comparison.pdf
Fig. 3: The grpah shows a comparison of our measurement of Calpha K* with previous measurements. The outer error bars represent the total uncertainty and the inner error bars are the statistical uncertainty only (where applicable).
-------------------------------------------------------
Plots shown at
DPF2002
by Jason Ladue
-
dpf2002.ps
Transparencies
-------------------------------------------------------
-
backtrd.eps
eeg mass distribution before (purple) and after (yellow) TRD cut
-------------------------------------------------------
-
backfit.eps
eeg mass distribution with background extrapolation
-------------------------------------------------------
-
ephotrat.eps
Energy of photon for KL->eeg (left) and the normalization mode, KL->pi0 pi0 pi0Dalitz (right)
-------------------------------------------------------
-
etotrat.eps
Total energy for KL->eeg (left) and the normalization mode, KL->pi0 pi0 pi0Dalitz (right)
-------------------------------------------------------
-
trkseprat.eps
Separation between tracks at the first drift chamber for KL->eeg (left) and the normalization mode, KL->pi0 pi0 pi0Dalitz (right).
-------------------------------------------------------
-
vtxchirat.eps
Vertex chisquare distributions for KL->eeg (left) and the normalization mode, KL->pi0 pi0 pi0Dalitz (right).
-------------------------------------------------------
-
zvtxrat.eps
Decay vertex distributions for KL->eeg (left) and the normalization mode, KL->pi0 pi0 pi0Dalitz (right).
-------------------------------------------------------
-
brworld.eps
Comparison of KL->eeg branching ratios between experiments
-------------------------------------------------------
-
meeratmcmany.eps
ee invariant mass distribution comparisons between data and MC with different alpha K*. Alpha K* = +0.20 (top left), 0.00 (top right), -0.16 (bottom left), and -0.36 (bottom right).
-------------------------------------------------------
-
meeratbest.eps
ee invariant mass distribution (top) and the data/MC ratio (bottom)
-------------------------------------------------------
-
akworld.eps
alpha K* measurements for NA48 eeg, KTeV eeg and mmg
-------------------------------------------------------
Send corrections to Taku Yamanaka.